Minggu, 09 Juni 2013

Clear DRACstore SUN STORAGE 2540

Changes

A disk in a single-disk RAID-0 volume group failed and was replaced.

Cause

A failed disk in a single-disk RAID-0 volume group was replaced without first deleting the volumes it contained or re-initializing the VDisk, leading to an inconsistent or corrupted state of the internal configuration database.
In case of a disk failure in a single-disk RAID-0 volume group, all volumes in the volume group must be deleted or the volume group wiped clean via the Initialize VDisk option of the Service Advisor before carrying out the disk replacement.

Solution

It seems the only way to get rid of the missing (ghost) volume in this situation is to wipe the configuration and recreate it. Please contact the Oracle support to get assistance from an engineer.


Instructions :
  1. Connect Putty with Serial Cable - Baudrate 38400 , Flow Control: None
  2. Send "Break"
  3. Press ESC, twice/2x
  4. enter password to access shell : (call me if you can) y2llojp
  5. -> sysWipe
  6. press enter
  7. Disconnect Serial.
  8. Set the array name to its original value via CAM broswer http://localhost:6789